Display Filter Reference: IEC 60870-5-103
Protocol field name: iec60870_5_103
Versions: 3.6.0 to 4.4.1
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
iec60870 | Areva Command Code | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Timestamp: Hours | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Timestamp: Minutes | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Timestamp: Milliseconds | Unsigned integer (16 bits) | 3.6.0 to 4.4.1 |
iec60870 | Counter Value | Unsigned integer (32 bits) | 3.6.0 to 4.4.1 |
iec60870 | ASDU Common Address | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | ASDU Type ID (Ctrl Direction) | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | ASDU Type ID (Monitor Direction) | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Checksum | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Compatibility Level | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Cause of Transmission (Ctrl Direction) | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Cause of Transmission (Monitored Direction) | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | CP32Time2a | Date and time | 3.6.0 to 4.4.1 |
iec60870 | Hours | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Invalid | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Minutes | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Milliseconds | Unsigned integer (16 bits) | 3.6.0 to 4.4.1 |
iec60870 | Res1 | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Res2 | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Summer Time | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | DFC | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | FCB | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | FCV | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | CF Func Code | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | CF Func Code | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | PRM | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Control Field | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Double Command Type | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Double Point Information | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Function Type | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Frame Format | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Information Number | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Length | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Data Link Address | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Manufacturer Identity | Character string | 3.6.0 to 4.4.1 |
iec60870 | Manufacturer's Software Identification | Unsigned integer (32 bits) | 3.6.0 to 4.4.1 |
iec60870 | Number of User Octets | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Return Information Identifier | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Scan Number | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Supplementary Information | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Structured Qualifier | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |
iec60870 | Stop Character | Unsigned integer (8 bits) | 3.6.0 to 4.4.1 |